  • In order to keep furnace temperature and the charges uniform of each element, before installation, resistance distribution must be carried out. The resistance deviation among elements of each set should be below ±5%.


  • As the element is very brittle, be careful while installing and maintaining to avoid any damage.


  • When starting to operate the furnace, raise voltage slowly and gradually, never give full load at one time, otherwise, the heating element will be damaged by overcurrent impulse.


  • To use the elements, you should prepare the adjustable transformer or SCR controller, voltage meter, current meter, and auto-control temperature meter etc. During the working, the voltage should be increased to keep the furnace at normal temperature because the resistance value will go up gradually caused by the oxidation of the element. When the voltage gets to the top limit of the transformer and the temperature is still low than the requirement, the furnace should be stopped, change the way of wire connection and then continue work.


  • In the course of long-term operation, if any individual heating element is damaged owing to certain reasons, which should be changed, you should replace it with a proper one whose resistance value corresponds to that of the old one, never use a new heating element random. If the heating element is much damaged or its resistance value increases too much and cannot reach the furnace temperature, it is better to replace all the heating elements with new ones. Test and mark the resistance value of the old elements having been replaced (with voltmeter and ammeter) and distribute them in low-temperature areas.