Practical Tips For Changing Silicon Carbide Heating Elements
Dec 20, 2021
Furnace type, design and cycling make a difference. Let’s answer this question by considering a mesh-belt copper-brazing furnace with a muffle operating at 2050°F (1120°C) in a hydrogen/nitrogen (75%/25%) atmosphere. The furnace is run six days a week with a typical belt loading of 10–12 lbs/linear foot (15–18 kg/linear meter). Typical element life is expected to be in the range of 12–24+ months. Here’s how to determine when its time to change elements:
1. Beginning with a change of elements, measure the amperage and voltage to the individual elements on a quarterly basis. Calculate their resistance and watt input to determine whether they are balanced or not. If a particular element shows erratic readings or large changes in resistance from one set of readings to the next, it is time to replace it. Note: Silicon carbide heating elements should be changed in sets depending on how many elements are in series with one another (sometimes in pairs, sometimes more).
2. Also, there is a relatively simple procedure that should be done to take the guesswork out of knowing when to change elements. With all new elements, lower the furnace temperature (and monitor it during this procedure) and place the power controller (SCR) in manual mode calling for 100% power. Take a digital meter with extra long leads and, CAREFULLY touching the element on either end, measure the voltage drop across the element. Note: Do not take this reading by touching the straps as they run slightly cooler and your reading won’t be as accurate. Measure the current using a clamp-on ammeter around the straps and calculate resistance and watt input. Record this information for future reference. When the elements have doubled in resistance, it is time to change elements. Repeat these measurements every quarter.
3. When you see that the elements have degenerated to about 2/3 of their original resistance value, it is time to change to the next highest tap on the transformer.
4. If you are fully “tapped up” – on the highest tap setting on the transformer – and a particular zone begins to “struggle” (when it has difficulty maintaining your temperature set point), then you know it’s time to change all of the elements in that zone.
Vsmile replacement heating element for Amann Girrbach Ceramill Term,Ceramill Term 2,DEKEMA BASIC and DEKAMA AUSTROMAT dental furnace are available now, We are dedicated to providing the best possible service for your equipment, and take pride in our reliable workmanship, experienced technicians, and friendly sales and service.and we are happy to provide over-the-phone tech support to customers. Need help finding the right part for your lab or clinic? please don't be hesitate to make us an inquiry.